Switching Power Supply / AC DC Power Supply / DC DC Power Supply / SMPS
Product Name:
60W Dual Output Switching Power Supply
Description:
Universal AC input/Full range.
Protections:Short circuit/Over load/Over voltage.
Cooling by free air convection.
LED indicator for power on.
Fixed switching frequency at 54KHz.
2 years warranty.
| MODEL | SKD-60A | SKD-60B | |||
| OUTPUT | DC VOLTAGE | 5V | 12V | 5V | 24V |
| RATED CURRENT | 4A | 3A | 3A | 1.8A | |
| CURRENT RANGE | 1 ~ 4A | 0.2 ~ 4A | 0.3 ~ 6A | 0.2 ~ 2.2A | |
| RATED POWER | 56W | 58W | |||
| RIPPLE & NOISE (max.) Note.2 | 75mVp-p | 150mVp-p | 75mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | CH1:4.75 ~ 5.5V | CH1:4.75 ~ 5.5V | |||
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±2.0% | ±5.0% | |
| LINE REGULATION | ±0.5% | ±1.0% | ±0.5% | ±0.5% | |
| LOAD REGULATION | ±0.5% | ±5.0% | ±0.5% | ±4.0% | |
| SETUP, RISE, HOLD TIME | 200ms,50ms, 20ms at full load | ||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC selected by switch 120 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||
| EFFICIENCY (Typ.) | 73% | 76% | |||
| AC CURRENT | 2A/115VAC 1A/230VAC | ||||
| INRUSH CURRENT (max.) | COLD START 18A/115VAC 36A/230VAC | ||||
| LEAKAGE CURRENT | <3.5mA / 240VAC | ||||
| PROTECTION | OVERLOAD | 105 ~ 150% rated output power. | |||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed. | |||||
| OVER VOLTAGE | 5V : 5.75 ~ 6.75V | ||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed. | |||||
| ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve) | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -20 ~ +85ºC , 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03%/ (0 ~ 50) on +5V output | ||||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
| SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL1012, UL60950, TUV EN60950 Approved | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
| HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | ||||
| OTHERS | MTBF | 301.2K hrs min. MIL-HDBK-217F (25ºC) | |||
| DIMENSION | 159*97*38mm (L*W*H) | ||||
| PACKING | 0.55Kg; 24pcs/13.2Kg/0.75CUFT | ||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 2. of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment mus. be re-confirmed that it still meet. | ||||